Vui lòng tham khảo thông số kỹ thuật và bảng giá sản phẩm
Pricelist
Features:
- 2 Channels, 4 Traces
- DC ~ 30MHz (GOS-6030/6031)
- DC ~ 50MHz (GOS-6050/6051)
- 1mV/DIV ~ 20V/DIV
- CRT Readout
- Cursor Measurement, 6 Digit Frequency Counter, 10 Sets Memory for Front Panel Setting Save & Recall (GOS-6031/6051)
- ALT MAG Function (x5, x10, x20)
- Vertical Mode Triggering
- TV Synchronization
- CH1 Signal Output, Z-axis Input
- Buzzer Alarm & LED Indicators
- Compact size (275W x 130H x 370D mm) and Front Panel Layout Groups for easy to use
Model | Description | ||
GOS-6030 | 30Mhz Analog Oscilloscope, Cursor | ||
GOS-6031 | 30Mhz Analog Oscilloscope, Cursor, Recall & Counter - Discontinued - replaced by Instek GDS-1062A or Instek GOS-635G | ||
GOS-6050 | 50Mhz Analog Oscilloscope, Cursor | ||
GOS-6051 | 50Mhz Analog Oscilloscope, Cursor, Recall & Counter |
SPECIFICATIONS
SPECIFICATIONS
|
|||||||||||||||||||||
CRT
|
Type
|
6-inch rectangular type with internal graticule; 0%, 10%, 90% and 100% markers. 8 x 10 DIV (1 DIV=1 cm)
|
|||||||||||||||||||
Accelerating Potential
|
GOS-6051/6050 approx.10kV
GOS-6031/6030 approx.2kV |
||||||||||||||||||||
INTEN and FOCUS
|
Front panel control
|
||||||||||||||||||||
Illumination
|
Provided (GOS-6031/6051)
|
||||||||||||||||||||
Trace Rotation
|
Provided
|
||||||||||||||||||||
Z-axis input
|
Sensitivity: at least 5V
|
||||||||||||||||||||
Polarity: positive going input decrease intensity
|
|||||||||||||||||||||
Usable frequency range: DC to 2MHz
|
|||||||||||||||||||||
Maximum input voltage: 30V (DC+AC peak) at 1kHz or less
|
|||||||||||||||||||||
GOS-6051/6050 Input impedance: approx. 33k£[
GOS-6031/6030 Input impedance: approx. 47k£[ |
|||||||||||||||||||||
|
|||||||||||||||||||||
VERTICAL SYSTEM
|
Sensitivity and Accuracy
|
1mV ~ 2mV/DIV + 5%, 5mV ~ 20V/DIV + 3%, 14 calibrated steps in 1-2-5 sequence
|
|||||||||||||||||||
Vernier Vertical Sensitivity
|
Continuously variable to 1/2.5 or less panel indicate value
|
||||||||||||||||||||
Bandwidth (-3dB) and Rise Time
|
|
||||||||||||||||||||
Maximum Input Voltage
|
400V (DC + AC peak) at 1kHz or less
|
||||||||||||||||||||
Input Coupling
|
AC, DC, GND
|
||||||||||||||||||||
Input Impedance
|
1M£[ + 2% // approx. 25pF
|
||||||||||||||||||||
Vertical Modes
|
CH1, CH2, DUAL (CHOP, ALT), ADD, CH2 INV
|
||||||||||||||||||||
CHOP Frequency
|
Approx. 250kHz
|
||||||||||||||||||||
Dynamic Range
|
GOS-6031/6030:8 DIV at 20MHz, 6 DIV at 30MHz
GOS-6051/6050:8 DIV at 40MHz, 6 DIV at 50MHz |
||||||||||||||||||||
|
|||||||||||||||||||||
HORIZONTAL SYSTEM
|
Sweep Time
|
0.2µS/DIV ~ 0.5S/DIV, 20 steps selectable in 1-2-5 sequence, continuous variable control between steps at least 1¡G2.5
|
|||||||||||||||||||
Accuracy
|
+ 3%, + 5% at x5, x10 MAG. + 8% at x20 MAG
|
||||||||||||||||||||
Sweep Magnification
|
x5, x10, x20 MAG
|
||||||||||||||||||||
Maximum Sweep Time
(at MAG) |
GOD-6051/6050: 20nS/DIV (10nS/DIV are uncalibrated)
|
||||||||||||||||||||
GOD-6031/6030: 100nS/DIV (10nS/DIV ~ 40nS/DIV are uncalibrated)
|
|||||||||||||||||||||
ALT-MAG Function
|
Available
|
||||||||||||||||||||
|
|||||||||||||||||||||
TRIGGER
|
Trigger Modes
|
AUTO, NORM, TV
|
|||||||||||||||||||
Trigger Source
|
VERT-MODE, CH1, CH2, LINE, EXT
|
||||||||||||||||||||
Trigger Coupling
|
AC, HFR, LFR, TV-V(-), TV-H(-)
|
||||||||||||||||||||
Trigger Slope
|
"+" or "-" polarity
|
||||||||||||||||||||
Trigger Sensitivity
|
|
||||||||||||||||||||
TV sync pulse more than 1 DIV (CH1, CH2, VERT-MODE) or 200mV(EXT)
|
|||||||||||||||||||||
External Trigger Input
|
Input Impedance¡GApprox. 1M£[ // 25pF (AC coupling)
|
||||||||||||||||||||
Max. input voltage¡G400V (DC + AC peak) at 1kHz
|
|||||||||||||||||||||
Hold-off Time
|
Variable
|
||||||||||||||||||||
|
|||||||||||||||||||||
X-Y OPERATION
|
Input
|
X-axis¡GCH1¡FY-axis¡GCH2
|
|||||||||||||||||||
Sensitivity
|
1mV/DIV ~ 20V/DIV
|
||||||||||||||||||||
Bandwidth
|
X-axis¡GDC ~ 500kHz (-3dB)
|
||||||||||||||||||||
Phase Difference
|
3º or less from DC to 50kHz
|
||||||||||||||||||||
|
|||||||||||||||||||||
OUTPUT SIGNAL
|
|||||||||||||||||||||
Trigger Signal Output
|
Voltage¡G approx. 20mV/DIV (with 50£[ terminated)¡F
Bandwidth¡G50Hz to at least 5MHz |
||||||||||||||||||||
Calibrator Output
|
Voltage¡G0.5V + 3%¡FFrequency¡Gapprox. 1kHz, Square wave
|
||||||||||||||||||||
|
|||||||||||||||||||||
CURSOR READOUT
|
Panel Setting Display
|
CH1/CH2 sensitivity, sweep time, trigger condition
|
|||||||||||||||||||
Panel Setting Save & Recall (GOS-6031/6051) |
10 sets
|
||||||||||||||||||||
Cursor Measurement
(GOS-6031/6051) |
Cursor measurement function¡G£GV, £GT, 1/£GT
|
||||||||||||||||||||
Cursor resolution¡G1/25 DIV¡F
Effective cursor range¡Gvertial: + 3 DIV, horizontal: + 4 DIV |
|||||||||||||||||||||
Frequency Counter
(GOS-6031/6051) |
Display digits¡GMax. 6-digits decimel
|
||||||||||||||||||||
Frequency range¡GGOS-6051¡G50Hz ~ 50MHz¡FAccuracy¡G+ 0.01%
Frequency range¡GGOS-6031¡G50Hz ~ 30MHz¡FAccuracy¡G+ 0.01% |
|||||||||||||||||||||
Measuring sensitivity¡Gmore than 2 DIV (measuring source selected from CH1 or CH2 as synchronous signal sources)
|
|||||||||||||||||||||
|
|||||||||||||||||||||
POWER SOURCE
|
AC 100V/120V/ 230V + 10%, 50/60Hz
|
||||||||||||||||||||
|
|||||||||||||||||||||
ACCESSORIES
|
Power cord x 1, Instruction manual x 1, Probes(10:1/1:1) x 2
|
||||||||||||||||||||
|
|||||||||||||||||||||