THÔNG SỐ KỸ THUẬT CHÍNH
- Băng thông 50MHz, 70MHz, 100MHz, 200MHz
- 2 hoặc 4 kênh Analog
- 1GS/s trên mọi kênh
- Lưu trữ 2.5 Kilopoint trên toàn kênh
Digital Storage Oscilloscopes
TDS2000C Series
Features & Benefits
Key Performance Specifications
- 200 MHz, 100 MHz, 70 MHz, 50 MHz Bandwidth Models
- 2- and 4-channel Models
- Up to 2 GS/s Sample Rate on All Channels
- 2.5k point Record Length on All Channels
- Advanced Triggers including Pulse Width Trigger and Line-selectable Video Trigger
Ease-of-Use Features
- 16 Automated Measurements, and FFT Analysis for Simplified Waveform Analysis
- Built-in Waveform Limit Testing
- Automated, Extended Data Logging Feature
- Autoset and Signal Auto-ranging
- Built-in Context-sensitive Help
- Probe Check Wizard
- Multiple-language User Interface
- 5.7 in. (144 mm) Active TFT Color Display
- Small Footprint and Lightweight – Only 4.9 in. (124 mm) Deep and 4.4 lb. (2 kg)
Connectivity
- USB 2.0 Host Port on the Front Panel for Quick and Easy Data Storage
- USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or Direct Printing to a PictBridge®-compatible Printer
- Includes National Instrument’s LabVIEW SignalExpress™ TE Limited Edition and Tektronix OpenChoice® Software for Connecting Your Bench
Lifetime Warranty*1
*1 Limitations apply. For terms and conditions, visit www.tektronix.com/lifetimewarranty.
Performance You Need at a Price You Can Afford
The TDS2000C Digital Storage Oscilloscope Series provides you with affordable performance in a compact design. Packed with standard features – including USB connectivity, 16 automated measurements, limit testing, data logging, and context-sensitive help – the TDS2000C Series oscilloscopes help you get more done, in less time.
Digital Precision for Accurate Measurements
Quickly and easily capture waveforms with advanced triggering.
See all the details other oscilloscopes might miss with Tektronix proprietary digital real-time sampling.
With up to 200 MHz bandwidth and 2 GS/s maximum sample rate, no other digital storage oscilloscope offers as much bandwidth and sample rate for the price. Tektronix proprietary sampling technology provides real-time sampling with a minimum of 10X oversampling on all channels, all the time to accurately capture your signals. Sampling performance is not reduced when using multiple channels.
Critical Tools for Troubleshooting Your Device
Quickly perform an FFT with the advanced math functions.
Advanced triggers – rising/falling edge, pulse width, and video – help you quickly isolate your signals of interest. Once you’ve captured a signal, advanced math capabilities and automated measurements can speed your analysis. Quickly perform an FFT or add, subtract, or multiply waveforms. Sixteen automated measurements quickly and reliably calculate important signal characteristics such as frequency or rise time, while the built-in Limit Test function enables you to easily identify problems in your signal.
Designed to Make Your Work Easy
The TDS2000C Series oscilloscopes are designed with the ease of use and familiar operation you have come to expect from Tektronix.
Intuitive Operation
The intuitive user interface with dedicated per-channel vertical controls, auto-setup, and auto-ranging makes these instruments easy to use, reducing learning time and increasing efficiency.
Help When You Need It, Where You Need It
The context-sensitive Help system provides important information specific to the task you are working on.
The built-in Help menu provides you with important information on your oscilloscope’s features and functions. Help is provided in the same languages as the user interface.
Probe Check Wizard
Check out your probe compensation before making measurements with just one button that starts a fast, easy procedure.
Limit Test
Limit Test provides a quick Pass/Fail comparison of any triggered input signal to a user-defined template.
The oscilloscope can automatically monitor source signals and output Pass or Fail results by judging whether the input waveform is within predefined boundaries. Specific actions can be triggered on violation including stopping waveform acquisition, stopping Limit Test functions, saving the failed waveform data or screen image to a USB memory device, or any combination of the above. This is an ideal solution for manufacturing or service applications where you need to make decisions quickly.
Flexible Data Transfer
Data Logging enables automatic saving of triggered waveforms.
Conveniently use your USB flash drive to store screenshots and waveform data.
The USB host port on the front panel enables you to save your instrument settings, screenshots, and waveform data in a flash. The built-in Data Logging feature means you can set up your oscilloscope to save user-specified triggered waveforms to a USB memory device for up to 24 hours. You can also select the "Infinite" option for continuous waveform monitoring. With this mode you can save your triggered waveforms to an external USB memory device without a duration limitation until the memory device is full. The oscilloscope will then guide you to insert another USB memory device to continue saving waveforms.
Easy PC Connectivity
Easily capture, save, and analyze measurement results with included National Instrument's LabVIEW SignalExpress, Limited Tektronix Edition software.
Easily capture, save, and analyze measurements results by connecting to your PC with the rear-panel USB device port and the included copy of OpenChoice PC Communications Software. Simply pull screen images and waveform data into the stand-alone desktop application or directly into Microsoft Word and Excel. Alternatively, if you prefer not to use your PC, you can simply print your image directly to any PictBridge-compatible printer.
Connect Your Bench for Intelligent Debug
Every TDS2000C Series oscilloscope ships with an included copy of the Limited Tektronix Edition of National Instrument’s LabVIEW SignalExpress for basic instrument control, data logging, and analysis.
SignalExpress supports the range of Tektronix bench instruments*2 enabling you to connect your entire test bench. You can then access the feature-rich tools packed into each instrument from one intuitive software interface. This allows you to automate complex measurements requiring multiple instruments, log data for an extended period of time, time-correlate data from multiple instruments, and easily capture and analyze your results, all from your PC. Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design.
Performance You Can Count On
In addition to industry-leading service and support, every TDS2000C Series oscilloscope comes backed with a Lifetime Warranty*1 as standard.
*1 Limitations apply. For terms and conditions, visit www.tektronix.com/lifetimewarranty.
*2 For a complete listing of Tektronix instruments supported by NI LabVIEW Signal Express, visit www.tektronix.com/signalexpress.
Characteristics
TDS2000C Series Digital Storage Oscilloscopes
|
TDS2001C |
TDS2002C |
TDS2004C |
TDS2012C |
TDS2014C |
TDS2022C |
TDS2024C |
---|---|---|---|---|---|---|---|
Display (QVGA LCD) |
TFT |
TFT |
TFT |
TFT |
TFT |
TFT |
TFT |
Bandwidth*3 |
50 MHz |
70 MHz |
70 MHz |
100 MHz |
100 MHz |
200 MHz |
200 MHz |
Channels |
2 |
2 |
4 |
2 |
4 |
2 |
4 |
External Trigger Input |
Included on all models |
||||||
Sample Rate on Each Channel |
500 MS/s |
1.0 GS/s |
1.0 GS/s |
2.0 GS/s |
2.0 GS/s |
2.0 GS/s |
2.0 GS/s |
Record Length |
2.5k points at all time bases on all models |
||||||
Vertical Resolution |
8 bits |
||||||
Vertical Sensitivity |
2 mV to 5 V/div on all models with calibrated fine adjustment |
||||||
DC Vertical Accuracy |
±3% on all models |
||||||
Vertical Zoom |
Vertically expand or compress a live or stopped waveform |
||||||
Maximum Input Voltage |
300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz |
||||||
Position Range |
2 mV to 200 mV/div +2 V >200 mV to 5 V/div +50 V |
||||||
Bandwidth Limit |
20 MHz for all models |
||||||
Input Coupling |
AC, DC, GND on all models |
||||||
Input Impedance |
1 MΩ in parallel with 20 pF |
||||||
Time Base Range |
5 ns to 50 s/div |
5 ns to 50 s/div |
5 ns to 50 s/div |
2.5 ns to 50 s/div |
2.5 ns to 50 s/div |
2.5 ns to 50 s/div |
2.5 ns to 50 s/div |
Time Base Accuracy |
50 ppm |
||||||
Horizontal Zoom |
Horizontally expand or compress a live or stopped waveform |
||||||
I/O Interfaces |
|||||||
USB Ports |
USB host port on front panel supports USB flash drives USB device port on back of instrument supports connection to PC and all PictBridge-compatible printers |
||||||
GPIB |
Optional |
||||||
Nonvolatile Storage |
|||||||
Reference Waveform Display |
(2) 2.5k point reference waveforms |
||||||
Waveform Storage without USB Flash Drive |
(2) 2.5k point |
(2) 2.5k point |
(4) 2.5k point |
(2) 2.5k point |
(4) 2.5k point |
(2) 2.5k point |
(4) 2.5k point |
Maximum USB Flash Drive Size |
64 GB |
||||||
Waveform Storage with USB Flash Drive |
96 or more reference waveforms per 8 MB |
||||||
Setups without USB Flash Drive |
10 front-panel setups |
||||||
Setups with USB Flash Drive |
4000 or more front-panel setups per 8 MB |
||||||
Screen Images with USB Flash Drive |
128 or more screen images per 8 MB (the number of images depends on file format selected) |
||||||
Save All with USB Flash Drive |
12 or more Save All operations per 8 MB A single Save All operation creates 3 to 9 files (setup, image, plus one file for each displayed waveform) |
*3 Bandwidth is 20 MHz at 2 mV/div, all models.
Acquisition Modes
Mode |
Description |
---|---|
Peak Detect |
High-frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) at all time base settings from 5 μs/div to 50 s/div |
Sample |
Sample data only |
Average |
Waveform averaged, selectable: 4, 16, 64, 128 |
Single Sequence |
Use the Single Sequence button to capture a single triggered acquisition sequence |
Roll |
At acquisition time base settings of >100 ms/div |
Trigger System
Characteristic |
Description |
---|---|
Trigger Modes |
Auto, Normal, Single Sequence |
Trigger Types
Trigger |
Description |
---|---|
Edge (Rising/Falling) |
Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject |
Video |
Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM) |
Pulse Width (or glitch) |
Trigger on a pulse width less than, greater than, equal to, or not equal to, a selectable time limit ranging from 33 ns to 10 s |
- Chi tiết
- Viết bởi TrongHuan Nguyen
- Chuyên mục: Tektronix
- Lượt xem: 8114