Handheld Oscilosscope Protek 860FC : 60MHz Analog bandwidth, Up to 200Ms/S sampling rates (100Ms/S Dual channel), High Resolution 3.8". 320 x 240 Pixel Color LCD, 125Kb record length for each channel, Real Time Data logger.
|
|
No. of inputs |
2 |
Analog Bandwidth |
60MHz |
Rise Time |
< 5.83nS |
Sensitivity |
5mV/Div to 100V/Div in (1-2-5 sequence) |
Resolution |
8 Bits |
Off set |
±5% from the center |
Vertical accuracy |
±3% |
Input Impedance |
1MW and ±20pF ±1.3pF |
Max. Input Volts |
300VDC or AC Peak |
Probe Attenuation |
x1 and x10 |
|
|
|
Sweep rates |
5nS/Div to 50S/Div |
Time base Accuracy |
±3% |
Posistion Range |
Pre-Trigger: 20Div Max. Post-Trigger: 1000 Div. |
Horizontal Modes: |
Main Sweep, XY |
Delta Time Measurement accuracy |
± 3% |
|
|
|
Acquisition modes |
Sample, Peak detect, Envelope, Average |
Sampling |
Real Time and Equivilent |
Sample Rate rates |
Up to 200Ms/s Single channel and 100Ms/S Dual Channel |
Equivilent Sampling Rate |
Up to 2.5Gs/S |
Sample Rate Accuracy |
±100ppm |
Record Length |
125KB/Channel |
Waveform Interpolation |
Dot, Linear, Sine and Pulse |
Peak Detect |
10nS minimum |
Averages |
2 to 256 |
|
|
|
Sensitivity |
0.5Div (DC to 5MHz) |
Advanced Trigger types |
Edge, Pulse width, Video |
Coupling |
AC, DC HF- Reject, LF- Reject, Noise Reject |
Mode |
Normal, Single, Roll and Auto |
Trigger Level range |
±20Div. from the center of the screen |
Trigger Level accuracy |
±0.4Div |
Trigger Sources |
ChA and ChB |
Trigger Level resolution |
500 Pixels |
|
|
|
Video Trigger sensitivity |
0.7Div |
Video Types |
NTSC, PAL and SECAM |
Video Trigger sources |
ChA or ChB |
Video Triggers |
Odd/Even frames, All frames, Line number (Lines 5 to 263 within a frame) |
|
|
|
Type |
P-P, Max, Amplitude, Top, Base, Pos/Neg. overshoot, Preshoot, RMS, Mean, One cycle Mean, Freq, Period, ±Width, ±Dutycycle, Rise/Fall time, Delay and Phase shift |
|
|
|
Dual Channel Math |
ChA + ChB, ChA - ChB, ChB - ChA, FFT |
Cursors |
Voltage: Y1, Y2, ∆V Time: Y1, Y2, ∆T |
|
|
|
Weighting |
Rectangular, Hamming, Hanning, Blackman-Harris |
Amplitude display |
1dB, 2dB, 5dB, 10dB and 20dB per Division |
Maximum Frequency |
1.25GHz |
|
|
|
Memory |
10 Waveforms and settings maybe stored and recalled |
|
|
|
Source |
DMM |
Range |
10 divisions on the LCD |
Record size |
256 data points |
Time span |
Auto ranging from 150 Sec to 20 days |
Measurement parameters |
Min., Max. or Avg. |
|
|
|
|
|
|
Ranges |
600mV to 1000V |
Accuracy |
±(0.3% +10d) |
Best Resolution |
100µV |
Input Impedance: |
10MW |
Overload protection |
1000V DC or AC peak |
|
|
|
Ranges |
6V to 600V |
Accuracy |
±(0.75% +10d) 50Hz to 1KHz ±(2.0% +10d) 1KHz to 30KHz |
Best Resolution |
1mV |
Input Impedance |
10MW |
Overload protection |
1000V DC or AC Peak |
|
|
|
Ranges |
600W to 60MW |
Accuracy |
±(0.5% +10d) |
Best Resolution |
100mW |
Overload Protection |
250VDC or AC peak |
|
|
|
Ranges |
60nF to 300µF |
Accuracy |
±(2.0% +10d) |
Best Resolution |
1pF |
|
|
|
Diode test |
Accuracy: ±2% |
Continuity |
Buzzer will sound: <60W |
dB measurements |
dBm reference values (in ohms) 2, 4, 8, 16, 50, 75, 93, 110, 125, 135, 150, 300, 600, 900, 1000, or 2000 |
Analog bargraph |
60 segments |
Current measurement with Optional current clamp |
600A |
|
|
|
Dimensions (L x W x D) |
4.2" x 8.3" x 2.2" |
Weight |
2.6lbs (1.18Kg) |
Power |
9VDC @ 1A AC/DC wall adapter 7.2V NiMh rechargeable , 2800mAH battery pack |
Standard accessories |
(2) x1 x10 Scope probes, Holster, USB cable and Software |
Optional accessories |
600A clamp on current transducer and carrying bag |
|